M4.401 Lifting module Strong

M4.401 Lifting module Strong max. lifting force 6,000 N
stroke from 200 to 400 mm
manual-hydraulic and electro-mechanical version

max. bending moment: 800 Nm
operations: foot pedal, foot switch or hand panel
pump strokes per 100 mm: 10..
lifting speed 5 .. 7 mm/s
control voltage: 24 VDC
supply voltage: 230 VAC

Items  (15)

  1. electro-mechanical version – with incremental stroke measuring system – (suitable for memory function and battery mode) – with smooth connecting cable, 0.3 m – control voltage 24 VDC – operation with foot switch or hand panel – max. lifting force 6000 N – max. bending moment 800 Nm – max. stroke 200 mm – as per data sheet M4.401
  2. electro-mechanical version – with integrated stroke end disconnection – (not suitable for synchronization control) – with coiled connecting cable, 1.5 m – control voltage 24 VDC – operation with foot switch or hand panel – max. lifting force 6000 N – max. bending moment 800 Nm – max. stroke 200 mm – as per data sheet M4.401
  3. electro-mechanical version – with incremental stroke measuring system – (suitable for synchronization control) – with smooth connecting cable, 2.5 m – control voltage 24 VDC – operation with foot switch or hand panel – max. lifting force 6000 N – max. bending moment 800 Nm – max. stroke 200 mm – as per data sheet M4.401
  4. manual-hydraulic version – operation with foot pedal – max. lifting force 6000 N – max. bending torque 800 Nm – max. stroke 200 mm – as per data sheet M4.401
  5. electro-mechanical version – with incremental stroke measuring system – (suitable for memory function) – with smooth connecting cable, 2.5 m – control voltage 24 VDC – operation with foot switch or hand panel – max. lifting force 6000 N – max. bending moment 800 Nm – max. stroke 200 mm – as per data sheet M4.401
  6. electro-mechanical version – with incremental stroke measuring system – (suitable for memory function and battery mode) – with smooth connecting cable, 0.3 m – control voltage 24 VDC – operation with foot switch or hand panel – max. lifting force 6000 N – max. bending moment 800 Nm – max. stroke 300 mm – as per data sheet M4.401
  7. electro-mechanical version – with integrated stroke end disconnection – (not suitable for synchronization control) – with coiled connecting cable, 1.5 m – control voltage 24 VDC – operation with foot switch or hand panel – max. lifting force 6000 N – max. bending moment 800 Nm – max. stroke 300 mm – as per data sheet M4.401
  8. electro-mechanical version – with incremental stroke measuring system – (suitable for synchronization control) – with smooth connecting cable, 2.5 m – control voltage 24 VDC – operation with foot switch or hand panel – max. lifting force 6000 N – max. bending moment 800 Nm – max. stroke 300 mm – as per data sheet M4.401
  9. manual-hydraulic version – operation with foot pedal – max. lifting force 6000 N – max. bending torque 800 Nm – max. stroke 300 mm – as per data sheet M4.401
  10. electro-mechanical version – with incremental stroke measuring system – (suitable for memory function) – with smooth connecting cable, 2.5 m – control voltage 24 VDC – operation with foot switch or hand panel – max. lifting force 6000 N – max. bending moment 800 Nm – max. stroke 300 mm – as per data sheet M4.401
Page:
  1. Previous
  2. 1
  3. 2